SYC-10-LA

Aviation obstruction lights

SYC-10-LA

SYCBA model SYC-32-LA is a medium intensity type A obstruction
light (10 Cd steady red burning light) used to enhance the visibility
of tall structures, such as wind turbines, towers, met masts, chimneys,
broadcast masts, bridges, buildings, etc.

Light source is achieved with high-efficiency LEDs, along with optical
lenses, to offer a high-intensity light with low consumption and a longlasting service life.

The body is manufactured with anodized aluminium alloy, painted with
powder coating for outstanding corrosion resistant properties.
The shell is made with Polycarbonate that is a tough, transparent UV
protected plastic material with exceptional strength, stiffness, and
that is impact resistant even at low temperatures.
The assembly is fully sealed and IP65 rated.
The lamp is supplied with bracket.

Opciones

Optionally the lights can be supplied with a twilight sensor. For monitoring and control the consumption, SYCBA MONITOR can be used, for further information contact SYCBA.

Plano de dimensiones

Especificaciones

Model SYCBA Light
Code SYC-10-LA
FAA compliance Type L-810
ICAO compliance LIOL type A
DC Power supply option 12VDC – 30VDC
AC Power supply options 220 VAC 50Hz – 120 VAC 60Hz
Working mode Steady burning
Light Intensity ≥10 Cd
Vertical beam 10°
Horizontal beam 360°
Light Color Red
Power consumption at 20 fpm ≤ 3.6 W
Operating Temperature -50 ºC to 70 ºC
IP Protection IP65
Weight 800gr (mounting bracket included)
Model
SYCBA Light
Code
SYC-32-LE
Type L-810
FAA compliance
ICAO compliance
LIOL type E
DC Power supply option
12VDC – 30VDC
AC Power supply options
AC Power supply options 220 VAC 50Hz – 120 VAC 60Hz
Working mode
Flashing 20, fpm
Light Intensity
≥32.5 Cd
Vertical beam
10°
Horizontal beam
360°
Light Color
Red
Power consumption at 20 fpm
≤ 1,2 W
Peak power
4 W
Twilight control
50/100 Lux
Ambient Temperature
IP Protection
IP65
Overall Size(mm)
(h.l.w) 218mm × 188mm × 125mm
Weight
0,8 Kg
Maximum wind speed survival
120 m/s

Aviso de utilización

Connect only to a power supply system within the rated parameters, otherwise the equipment could be damaged.
After its installation and adjustment, the device must be verified. To avoid any leaks, the O-ring must be correctly tighten
using the shell screws.
To prevent any major complication and/or injuries, only trained personal should carry out the maintenance.
Please follow all the country-specific regulations while working with the device, also, be advised of the next safety
guidelines:
1. Disconnect all power supplies
2. Reconnection
3. Ascertain the voltage-free operation
4. Carry out earthing and short-circuiting
5. Isolate all adjacent live parts

Para más información: